KerfPlot
Measurement units

Cutting a birdsmouth that passes inspection

A birdsmouth is two short cuts, but they decide how the roof bears on the wall, how much rafter is left at its most stressed point, and whether every rafter in the roof lines up. This guide covers the IRC R802 rules that govern the notch and the layout math that keeps commons, hips and jacks in one plane.

Updated

Free tool for this guideRafters & birdsmouthsSeat cuts that sit flat on the plate.

Anatomy of the birdsmouth

The birdsmouth is a notch near the foot of a rafter. The seat cut is level and sits on the top plate; the heel cut is plumb and bears against the outside face of the wall. Everything above the inside corner of the notch, measured plumb from the outside of the wall to the top edge of the rafter, is the height above plate, or HAP. The material left below the notch, measured square to the rafter edge, is what carries the reaction into the wall.

Pitch angle
φ = atan(rise / 12)
Seat length on the plate
s = min(plate width, (D / 4) / sin φ)
Heel cut height
h = s · tan φ
Notch depth square to the edge
d = s · sin φ
Height above plate
HAP = D / cos φ − h

D is the actual depth of the rafter, 7-1/4" for a 2×8, never the nominal 8". The seat is as long as the plate is wide unless that would make the notch deeper than the code allows, in which case the seat is shortened and the rafter bears on part of the plate.

The three IRC R802 rules

The rafter sections did not move in the 2024 renumbering, so the same citations apply to both the 2024 and 2021 IRC.

RuleRequirementApplies to
R802.6 bearing≥ 1-1/2" on wood or metal; ≥ 3" on masonry or concreteEvery rafter end
R802.7.1 end notchNotch depth ≤ D/4 of the actual rafter depthSawn-lumber rafters notched at the end
R802.7.1.1 cantileverRemaining depth ≥ 3-1/2" and cantilever ≤ 24"Notches on cantilevered (overhang) portions
R802.7.2 engineeredNotching only as the manufacturer permitsI-joists, LVL, glulam, trusses
IRC rafter notch and bearing rules

In practice, the D/4 cap governs on steep roofs and the plate width governs on shallow ones. The cantilever exception matters when a rafter with an overhang has a deep seat cut: the notch may exceed D/4 if at least 3-1/2" of rafter remains above it and the overhang beyond the wall is no more than 24" measured along the rafter.

Worked numbers: 2×8 rafters on a 2×6 wall

A 2×8 rafter has D = 7-1/4", so the end-notch limit is 1-13/16" (1.8125"). The 2×6 wall plate is 5-1/2" wide. Running the formulas at four pitches shows where each rule takes over.

PitchφSeat sHeel hNotch dHAPGoverns
4/1218.43°5.500"1.833"1.739"5.809"Plate width
6/1226.57°4.053"2.026"1.813"6.079"D/4
8/1233.69°3.268"2.178"1.813"6.535"D/4
12/1245.00°2.563"2.563"1.813"7.690"D/4
2×8 rafter (D = 7.25"), 5-1/2" plate

Every seat in the table is longer than 1-1/2", so R802.6 bearing passes on a wood plate. At 12/12 the rafter bears on less than half of the plate; that is legal, and it is the price of keeping 75% of the rafter depth at the wall.

Laying out with a fixed HAP

On a roof with any variation in plate height or rafter depth, frame to a constant HAP rather than a constant seat length. Choose the HAP once from the table, then on every common rafter measure that distance down the plumb line from the top edge and draw the seat cut from there. Rafters with a slightly deeper or shallower crown still put their top edges in the same plane, which is what the sheathing sees.

  1. Draw the ridge-face plumb cut and step off the line to ridge face from it along the top edge. Half the ridge is already deducted from that number.
  2. Draw the plumb heel line at the outside of the wall.
  3. Measure the HAP down the heel line from the top edge and draw the level seat line from that point.
  4. Check that the notch depth, square to the edge, is within D/4 (or the cantilever exception) before cutting.
  5. Cut the first rafter, test it at both ends of the building, then use it as the pattern.

Hip rafters and the 16.97" unit run

On a hip roof with equal pitches meeting at a 90° corner, the hip runs diagonally across the plan. For every 12" of common run, the hip travels the diagonal of a 12" square, 12√2 = 16.97". The hip’s unit rise is the same as the commons’, so its pitch is rise per 16.97 rather than per 12, and its length per foot of common run is the diagonal of rise and 16.97.

Hip unit run
12 · √2 = 16.97"
Hip length per foot of common run
√(16.97² + rise²)
Hip factor
√(2 + (rise / 12)²)
Common factor
√(1 + (rise / 12)²)
PitchCommon lengthHip lengthHip factor
4/1212.65"17.44"1.453
6/1213.42"18.00"1.500
8/1214.42"18.76"1.564
12/1216.97"20.78"1.732
Per foot of common run

A 6/12 hip over a 10' common run (120") is 120 × 1.5 = 180" of line length before shortening, against 134.16" for the common. Shorten the hip at the ridge to suit the framing detail (typically half the 45° thickness of the ridge or the common it frames against), and either back the hip (bevel both top edges) or drop it so its top edges land in the roof planes. For a 1-1/2" hip at 6/12 the drop is 0.75 × 6 ÷ 16.97 ≈ 1/4".

Jack rafters and the common difference

Jack rafters run from the plate to the hip at the same pitch as the commons, each one shorter than the last by a fixed amount, the common difference. Because jacks are laid out on the same on-center spacing as the commons, the difference is just that spacing measured along the slope.

Common difference
Δ = spacing / cos φ
Side (cheek) cut on the jack
atan(cos φ), measured from square
Pitch16" on center24" on center
4/1216.87"25.30"
6/1217.89"26.83"
8/1219.23"28.84"
12/1222.63"33.94"
Jack rafter common difference

Lay out the longest jack as a common rafter, shorten it at the hip by half the hip’s 45° thickness (1-1/16" level for a 1-1/2" hip, converted along the slope by dividing by cos φ), then subtract one common difference for each jack toward the corner. Cut jacks in left and right pairs; the cheek cut is mirrored on each side of the hip.

Questions from the shop

Can I make the birdsmouth deeper to get full bearing on a 2×6 wall?

Not on a non-cantilevered rafter end if it exceeds D/4. Use a deeper rafter, a beveled plate, or a manufactured rafter tie instead, or confirm the R802.7.1.1 cantilever conditions are met.

Does R802.7.1 apply to I-joist or LVL rafters?

No. R802.7.2 requires engineered members to be notched only as the manufacturer allows, and many prohibit birdsmouth cuts entirely in favor of beveled bearing plates.

Why use 16.97 instead of 17 for the hip?

12√2 is 16.9706. Rounding to 17 adds about 0.03" of run per foot, which is roughly 1/3" of extra hip length over a 12-foot common run, enough to push the hip past the ridge.

More in Stairs and roofs